Description
Weighing Indicator XK3190-D10
Weighing indicator XK3190-D10 adopts high precision ∑-Δ A/D conversion technology, widely applied in electronic floor scale, electronic truck scale, static railway scale and so on alike static weighing system equipped with 1~8 load cell.
Option: D10M (Shell Aluminum), D10Q (Shell Plastic ABS).
Technical parameter
Class: OIML Class III, N=5000.
A/D conversion method: ∑-Δ.
A/D conversion speed: 200 times/sec.
Input signal range: -30 mV ~ 30 mV.
Max. connection number of load cell: 8 at 350 ohm or 16 at 700 ohm.
Load cell connection mode: 6 wire, auto compensation for distance ≤ 50 meters.
Verified counts: 3.000.
Readability:30.000.
Max.internal resolution: 600.000.
Display: 7 bits LED display 7 status indications, 3 power indicators.
Clock: real clock without effect when power off.
Scoreboard interface (Standard): Serially sending by 20mA current loop with baud rate 600, transmission distance ≤ 2.000 meters.
Communication interface( RS232 C standard; RS422 optional): Serial communication interface, with selectable baud rate by continuous sending method or on command method.
Print interface (Standard): Parallel sending, able to connect with wide-line printer model KX-P1121, KX-P1131, LQ300K; micro printer for model D10P.
Power supply: AC 187~242V,49~51Hz; DC 6V/10Ah battery.
Connect Load cell with Jack Load cell DB9 (9 pin) on D10M
#Pin | 1 | 2 | 5 | 6 | 7 | 8 | 9 |
Description | EXC- | SEN- | SHIELD | EXC+ | SEN+ | SIG- | SIG+ |
Shorted #1 & #2, #6 & #7 when Load cell 4 core.