Description
Load cells MKCells CLC 30t
Basic device of the up-to-date weight measuring systems is load cells, construction of which is based on resilient mechanical member which is subject to deformation with overlaid on it strain-gauge bridge consisting of resistive-strain sensors connected in different electric networks.
With effect of external load to sensor as a result of deformation symmetry of measuring bridge is upset and electrical signal proportional to applied effect to sensor is appeared at measuring terminals.
Load cell CLC is one of the most popular models of load cells submitting by manufacturer MKCells . It applies for railway and truck scales.
The present model of load cells possesses advantages such as explosion safety, impact resistance and high accuracy.
Brands/Trade Mark: SNK-Keli, AMCells, MKCells.
Application in truck scales, rail weight scales, Silo scales.
Type of CLC is Canister Load Cells.
Orange/SS Cable (φ6mm):
Exc+ | Exc- | Sig+ | Sig- | shield |
Blue | Black | White | Red | Yellow |
Engineering data
Rated load (t) | 10, 15, 20, 25, 30, 40, 50 |
Accuracy class | С3 |
Sensitivity | 2.0 ± 0.002 mV/V |
Non-linearity | ± 0.03% F.S |
Hysteresis error | ± 0.03% F.S |
Creep (30min) | ± 0.02% F.S |
TC ZERO | ± 0.02% F.S/10ºС |
TC INTERVAL | ± 0.02% F.S/10ºС |
Input resistance | 1150 ± 20 Ω |
Output resistance | 1000 ± 3Ω |
Insulation resistance | ≥5000 mΩ |
Operating temperature rated range | – 10 ~ + 40ºС |
Temperature service range | – 30 ~ + 70ºС |
Safety load limit | 150% F.S |
Breaking load | 200% F.S |
Excitation rated range | 10 ~ 12 V DC |
Protection class | IP68 |
Material | Alloyed steel |
Stainless steel | |
Cable Length | 8m(10t); 10m (15t) |
12m (20-25t) | |
14m (30t); 16m (40-50t) |
Houphouet Kouassi –
Hi Sir.
I am looking for digital load cells.
The CLC-D 30t digital load is ok for me.
Please could you tell me which indicator is to be used with your digital load cells ?.
Make a proforma invoice for:
20 pcs CLC-D load cells 30t.
3 pcs indicators (Model to be chosen according to you).
3 pcs junction boxes for 8 digital load cells.
My Company is Nzotec
Country is Cote d’Ivoire (Ivory Coast)
Town is Abidjan
Best regards
ThaiVu –
Good, the indicator for CLC-D load cell is MK-Di01.