Description
Load cells AmCells KLC 30tf
Basic device of the up-to-date weight measuring systems is load cells, construction of which is based on resilient mechanical member which is subject to deformation with overlaid on it strain-gauge bridge consisting of resistive-strain sensors connected in different electric networks.
With effect of external load to sensor as a result of deformation symmetry of measuring bridge is upset and electrical signal proportional to applied effect to sensor is appeared at measuring terminals.
Load cell KLC is one of the most popular models of load cells submitting by manufacturer MKCells . It applies for railway and truck scales.
The present model of load cells possesses advantages such as explosion safety, impact resistance and high accuracy.
Brands/Trade Mark: AMCells
Application in truck scales, rail weight scales, Silo scales.
Type of KLC is Canister Load Cells, stainless steel single column compression load cell. It is good self-centering, fast dynamic response, and strong anti-overload capability, as well as simple to install, and easy to use.
Interchangeable Products:
Flintec RC3
Rice Lake RL80453 – 100K
Toledo SLC610 (15T-22.5T)
Black Cable (φ6mm):
Exc+ | Exc- | Sig+ | Sig- | Shield |
Red | Black | Green | White | Yellow |
Engineering data
Rated load (t) | 20, 30, 40, 50 |
Accuracy class | С3 |
Sensitivity | 2.0 ± 0.005 mV/V |
Non-linearity | ± 0.03% F.S |
Hysteresis error | ± 0.03% F.S |
Creep (30min) | ± 0.02% F.S |
TC ZERO | ± 0.02% F.S/10ºС |
TC INTERVAL | ± 0.02% F.S/10ºС |
Input resistance | 1150 ± 5 Ω |
Output resistance | 1000 ± 5Ω |
Insulation resistance | ≥5000 mΩ |
Operating temperature rated range | – 10 ~ + 40ºС |
Temperature service range | – 30 ~ + 70ºС |
Safety load limit | 150% F.S |
Breaking load | 200% F.S |
Excitation rated range | 10 ~ 12 V DC |
Protection class | IP68 |
Material | Stainless steel |
Cable Length | 14 met |
Dimension (mm)\

Reviews