Description
Load cells ASC 30tf OIML C5
Basic device of the up-to-date weight measuring systems is load cells, construction of which is based on resilient mechanical member which is subject to deformation with overlaid on it strain-gauge bridge consisting of resistive-strain sensors connected in different electric networks.
With effect of external load to sensor as a result of deformation symmetry of measuring bridge is upset and electrical signal proportional to applied effect to sensor is appeared at measuring terminals.
Load cell ASC is one of the most popular models of load cells submitting by manufacturer CASC (China).
Compression, fast dynamic response, strong anti-overload capability.
The present model of load cells possesses advantages such as explosion safety, impact resistance and high accuracy.
Brands/Trade Mark: KALA (USA brand).
International Certifications: OIML Approved.
Suitable for electronic truck scale, dynamic railroad scale, big capacity hopper scale, etc.
Type of ASC is AeroSpace Canister Column Load Cells.
Black Cable (φ6mm): Braided shield 4-wire round cable with PVC-jacket, Cable length 14m.
Shipping package : 26.5 x 22 x 24 cm / 6.4 kg.
| Exc+ | Exc- | Sig+ | Sig- | Shield |
| Red | Black | Green | White | Yellow |
Engineering data
| Max. Capacity | tf | 10, 20, 30 | |
| Rated output | mV/V | 2.0 ± 0.005 | |
| Zero balance | mV/V | 0.0 ± 0.02 | |
| Combined Error | %FS | 0.02% | |
| Repeatability | %FS | 0.02% | |
| Creep (30min.) | %FS | 0.02% | |
| Temperature effect on | Zero value | %FS/10℃ | 0.02% |
| Output value | %FS/10℃ | 0.02% | |
| Excitation | Recommended | V | 10 |
| Maximum | V | 15 | |
| Resistance | Input | Ω | 700 ± 5 |
| Output | Ω | 700 ± 5 | |
| Insulation | MΩ | >2000 @50VDC | |
| Compensated temp. range | ℃ | -10 ~ +40 | |
| Operating temp. range | ℃ | -40 ~ +80 | |
Dimensions and Accessories (mm)