Keli and Yaohua Indicator Compatibility
Analog indicators from both makers share the same DB9 load cell pinout and the same calibration sequence, so swapping one for the other needs no rewiring.
Truck Scales, Load cells, Truck Scales Software.

Analog indicators from both makers share the same DB9 load cell pinout and the same calibration sequence, so swapping one for the other needs no rewiring.

A field replacement on a concrete batching plant: PT650D specification, the 0-10 V analog link to the PLC, fitting a Keli XK3101E into the same connector, and the voltage drop to watch for.